Manual for ZGA SERIES - Troubleshooting and error codes + PDF Download

Manual for ZGA SERIES - Troubleshooting and error codes + PDF Download

Brand: Generic

Category: Home HVAC System

Manual Type:

Language:

Uploaded: April 1, 2025, 12:48 a.m.

Manual Publish Date: 2016-02

Warranty Summary

No warranty information provided in this manual.

Heating Start-up:

  1. Set thermostat to HEAT.
  2. Ignition control checks safety circuits.
  3. Combustion air inducer purges exhaust.
  4. Ignition control activates gas valve and spark.
  5. Flame is sensed, blower starts after delay.

Cooling Start-up:

  1. Set thermostat to COOL.
  2. Compressor and condenser fan are energized.
  3. For economizer units, outdoor air is used if suitable, otherwise, compressor runs.
  4. Blower operates to circulate cooled air.

Troubleshooting and error codes

LED STATUS
Slow Flash Normal operation. No call for heat.
Fast Flash Normal operation. Call for heat.
Steady Off Internal Control Fault, No Power To Board or Gas Valve Relay Fault
Steady On Control Internal Failure.
2 Flashes Lockout. Failed to detect or sustain flame.
3 Flashes Rollout switch open / Prove switch open or closed.
4 Flashes Primary High Limit switch open.
5 Flashes Flame sensed but gas valve not open.

Troubleshooting and error codes

LED STATUS
Slow Flash Normal operation. No call for heat.
Fast Flash Normal operation. Call for heat.
Steady Off Internal Control Fault, No Power To Board or Gas Valve Relay Fault
Steady On Control Internal Failure.
2 Flashes Lockout. Failed to detect or sustain flame.
3 Flashes Rollout switch open / Prove switch open or closed.
4 Flashes Primary High Limit switch open.
5 Flashes Flame sensed but gas valve not open.