Manual for 4SHP14/15

Brand: Allied Air Enterprises

Category: Heat Pump

Manual Type:

Language:

Uploaded: April 1, 2025, 12:48 a.m.

Warranty Summary

Warranty information is not provided in this installation manual; consult your dealer or product documentation for warranty details.

Thermostat Control: The system is controlled by a room thermostat, cycling the outdoor unit and indoor blower on demand. The blower can operate continuously if the thermostat's fan switch is set to the 'ON' position.

Emergency Heat: Some thermostats include an emergency heat function for use when outdoor unit isolation is needed or when auxiliary electric heat is staged by outdoor thermostats.

Defrost Cycle: The system automatically defrosts the outdoor coil when frost is detected, with a defrost cycle lasting 5-15 minutes. Steam may be visible during defrost, which is normal.

Power Outage Considerations: If the outdoor temperature is below 50°F and power has been out for over an hour, set the thermostat to 'Emergency Heat' for at least 6 hours upon power restoration to stabilize system pressures before resuming normal heat pump operation.

Troubleshooting and error codes

Responsive Table
Mode Green LED (DS2) Red LED (DS1)
No power to control Off Off
Normal operation / power to control Simultaneous slow flash
Anti-short cycle lockout Alternating slow flash
Low pressure switch fault Off Slow flash
Low pressure switch lockout Off On
High pressure switch fault Slow flash Off
High pressure switch lockout On Off

Troubleshooting and error codes

Responsive Table
Mode Green LED (DS2) Red LED (DS1)
No power to control Off Off
Normal operation / power to control Simultaneous slow flash
Anti-short cycle lockout Alternating slow flash
Low pressure switch fault Off Slow flash
Low pressure switch lockout Off On
High pressure switch fault Slow flash Off
High pressure switch lockout On Off