Manual for A96US2V

Brand: Allied Air Enterprises

Category: Furnace

Manual Type:

Language:

Uploaded: April 1, 2025, 12:48 a.m.

Warranty Summary

None

The A96US2V furnace utilizes an automatic hot surface ignition system. Upon a thermostat call for heat, the combustion air inducer starts, followed by a pre-purge. The hot surface ignitor then energizes, and after a warm-up period, the gas valve opens, initiating combustion. A flame sensor verifies ignition. If the flame is not detected, the ignition sequence repeats a few times before lockout. For heating, the indoor blower operates at speeds determined by DIP switch settings or Comfort Sync™™ thermostat commands, ensuring efficient and comfortable heating.

Troubleshooting and error codes

Code Diagnostic Codes/Status of Equipment Action Required to Clear and Recover
No change (idle)* No change (idle)* Remain in idle mode
Solid "E" Solid "E" Enter diagnostic recall mode
Solid "D" Solid "D" Discharge air installed
Solid "F" Solid "F" Enter flame signal mode
Solid "P" (variable speed only) Solid "P" (variable speed only) Program unit capacity/size (Unit Code)**

Troubleshooting and error codes

Code Diagnostic Codes/Status of Equipment Action Required to Clear and Recover
No change (idle)* No change (idle)* Remain in idle mode
Solid "E" Solid "E" Enter diagnostic recall mode
Solid "D" Solid "D" Discharge air installed
Solid "F" Solid "F" Enter flame signal mode
Solid "P" (variable speed only) Solid "P" (variable speed only) Program unit capacity/size (Unit Code)**