The manufacturer does not accept responsibility for inappropriate use or injury caused by incorrect installation.
This manual provides instructions for operating and maintaining a SIEMENS induction cooktop.
Key features and operations include:
Always refer to the safety instructions before operating the appliance.
| Visual indication | Fault | Measure |
|---|---|---|
| F0 | An internal error was produced while the hob was working. | Disconnect the cooking hob from the mains. Wait a few seconds before connecting it again. If the symbol continues to appear contact the technical assistance service. |
| F2 | The cooking hob is too hot and has turned off. | Remove the cookware from the front cooking zones. F2 it is turned off by touching the control surface if the hob has cooled down sufficiently. |
| F4 | The cooking hob is too hot and has turned off. | Check whether there is any hot cookware on the control panel. Remove the cookware from the control panel. Wait a few minutes until the control panel has cooled a little. If after connection F4 appears again, call the technical assistance service. |
| F8 | The cooking zone has been working at a high power and continuously for too long. | Automatic time limitation has been activated. To continue cooking touch any sensor. |
| C1/C3 | The power voltage is too low. | Deactivate the hob. Wait a few seconds before connecting it again. If the indication continues, contact your electricity supplier. |
| U400 | The cooking zone has overheated. | It has been automatically deactivated to protect your hob. Wait a few minutes for it to cool down and switch it back on again. |
| E-display and numbers | There is a fault in the electronics. | Disconnect the appliance from the mains and reconnect it. Consult the after-sales service if the display appears again. |