The SHARP AX-GX2T(R) and AX-GX2T(W) water oven offers various heating modes including Microwave, Oven, Grill, Steam, and combinations. Users can select pre-programmed settings or adjust time and temperature manually. The control panel features buttons for starting, stopping, defrosting, and setting temperature. Water supply and drainage are managed through a dedicated reservoir and dew tray. The oven also includes features like a convection heater, magnetron, and various fans for optimal cooking performance.
| Error display | EE code | Detail of error | Error condition | Application menu | Check method | Check timing from heating start | Note |
|---|---|---|---|---|---|---|---|
| U04 | 04 | Oven temperature is high. | Oven temperature is too high | fermentation | Thermistor (Oven) | After 1sec. | "高温" is blinking in the display. When oven temperature is turned under 90C, error is released. |
| U11 | 0B | Water exist in the water tank | Water exist in the water tank at drain mode | drain mode | Water level sensor | After 1sec | |
| U15 | 0F | Water tank is frozen | Engine heater temperature is too low. | Steam mode water oven water grill | Thermister (Oven) | immediately | |
| blinking | 0A | Shortage of Water | Water in the water tank isn't enough. | Steam mode water oven water grill | Water level sensor | Auto mode: after 30 sec manual mode: within 7 sec | |
| Error dis- play | EE code | Detail of error | Error condition | Application menu | Check method | Check timing | Note |
| C00 | Matching error | The control unit and/or display unit is not for this model. | Plug in | ||||
| C01 | 888 | Thermister (Oven) error | Thermister (Oven) is short or open. | Oven mode Grill mode | Immediately | ||
| C02 | 888 | Humidity sensor error | Humidity sensor is short or open. | Microwave mode (Humidity sensor menu) | After 16 sec | ||
| C05 | 888 | Engine heater error | Engine heater temperature is too high. | Steam mode Water oven Water grill | Always | ||
| C07 | 888 | Relay monitor error | Error condition microwave mode: when convection heater or engine heater operate. all relay is off: when convection heater or engine heater operate both convection heater and engine heater operate. | Microwave mode: immediately Oven, Grill mode: when heater is off | |||
| 01(Ad- dress 05) | Antenna error | Antenna motor or antenna switch does not work. | Microwave mode | When antenna error is detected, output of microwave is stopped. | |||
| C12 | 888 | Thermister (Engine) error | Thermister (Engine) is open. | Steam mode Water oven Water grill | When engine heater operates more than 30sec. | ||
| C14 | (reset) | EEPROM error (EEPROM data verification error) | EEPROM Read data is not same as EEPROM write data. Something is burn- ing in the oven. | PWB short check program | Short check program Plug in | After 7 min | |
| Humidity ladder level is too low. |