Guarantee is 12 months from purchase date, proof of which is required for any claim.
START UP AND SHUTDOWN: Press POWER to turn the unit ON or OFF.
OPERATION MODES: Select COOL to lower temperature, FAN to circulate air, or DRY for dehumidifying. SLEEP mode activates only via remote and is available in COOL mode.
COOLING: Select COOL mode, adjust temperature (16°C-32°C) using UP/DOWN buttons, and set fan speed (HIGH/LOW). Airflow direction is adjusted via louvres.
VENTILATE: Select FAN mode and desired fan speed. Air is circulated but not cooled.
DRYING: Select DRY mode, connect drain hose. Fan speed is fixed at low.
TIMER: Set the unit to START or STOP automatically (1-24 hours) using the TIMER button and UP/DOWN controls.
AUTO DEFROST: Unit automatically defrosts at low temperatures. POWER indicator blinks during defrost.
OVERLOAD PROTECTION: A three-minute delay prevents compressor restart after power loss.
MANUAL DRAINAGE: Switch off, unplug, move to a suitable location, remove drain plug to empty water tank. Replace plug securely.
CONTINUOUS DRAINAGE: Connect drain hose to water outlet and route to a container or drain. Ensure hose is straight and angled downwards.
| SYMPTOM | POSSIBLE CAUSE | REMEDY |
|---|---|---|
| The unit is not working | No power | Connect to power source and turn the unit ON |
| Full water indicator is illuminated | Drain the water | |
| The unit works with reduced capacity | Low room temperature | Change the set temperature |
| Dirty air filter | Clean the air filter as required | |
| Air ducts are blocked | Clear obstacles. Re-position unit into clear space | |
| Doors or windows open | Close the doors and windows | |
| Incorrect mode and temperature selected | Select correct mode and temperature to suit desired application | |
| Detached exhaust hose | Securely reattach exhaust hose | |
| Water leakage | Spillage when moving the unit | Empty the water tank before moving the unit |
| The drain hose is kinked or bent | Straighten the drain hose | |
| Excessive noise | The unit is on an uneven surface | Place the unit onto a flat horizontal surface |
| Loose, vibrating parts | Check for loose parts and re-tighten | |
| Water flowing sound | Normal sound of refrigerant flowing | |
| Error codes | E0 Communication faults between main PCB and display PCB | Contact Sealey service centre |
| E1 Ambient temperature sensor fail | Contact Sealey service centre | |
| E2 Coil temperate sensor failures | Contact Sealey service centre | |
| Ft Condensate water high level alarm | Drain the water |