Manual for SAC16000

Manual for SAC16000

Brand: SEALEY

Category: Air Conditioner

Document Type: Manual

Language: EN

Uploaded: Nov. 21, 2025, 8:35 p.m.

Manual Publish Date: 2024-01-03

Warranty Information

The warranty is 12 months from the purchase date, proof of which is required for any claim.

Operation Summary

This portable air conditioner offers four functions: cooling, dehumidifying, fan, and heating. It features a soft-touch control panel with an LED display and remote control. Key features include a built-in 24-hour timer, sleep mode, and a self-evaporating system. The unit operates within a temperature range of 16-32°C (cooling) and has an auto-defrost function. It is equipped with castor wheels for easy manoeuvrability.

Cooling Mode: Lowers room temperature, adjustable between 16-32°C with selectable fan speeds and swing function.

Heating Mode: Warms the room, adjustable temperature and fan speed.

Ventilating Mode: Circulates room air without cooling.

Drying/Dehumidifying Mode: Removes moisture (up to 50.4L/day), requires drainage hose connection for continuous operation.

Sleep Mode: Activates in cool or heat mode, gradually adjusts temperature and dims indicators for quiet operation.

Timer: Allows automatic start/stop scheduling.

Automatic Defrost: Activates at low temperatures to prevent frost buildup.

Drainage: Manual or continuous options available.

Troubleshooting and error codes

SYMPTOM INSPECTION SOLUTION
The unit is not working Check the mains supply Insert the power cord securely into the wall outlet
Check if the water level indicator lights up? Empty the drain pan. See Section 5.10
The unit works with reduced capacity Check the room temperature. The range of operating temperature is 5-35°C
Check if the air duct is blocked Clear the obstacle.
Check the air filter for dirt Clean the air filter. See Section 7
Check if the room door or window is open. Keep the door and windows closed.
Check if the desired operating mode is selected and temperature is properly set. Set the mode and temperature at proper set-point See Section 5
Water Leakage The exhaust hose is detached. Make sure the exhaust hose is securely attached.
Overflow while moving the unit. Empty the water tank before transport.
Check if the drain hose is kinked or bent. Straighten the hose to avoid a trap existing.
Excessive Noise Check if the unit is securely positioned. Place the unit on horizontal and firm ground.
Check if any loose, vibrating parts. Secure and tighten the parts.
Noise sounds like water flowing. Noise comes from flowing refrigerant. This is normal.
Error Codes E0 Communication faults between main PCB and display PСВ.
E1 Ambient temperature sensor failure
E2 Coil temperature sensor failures.
Ft Condensate water high level alarm.