The warranty is 12 months from the purchase date, proof of which is required for any claim.
This portable air conditioner offers four functions: cooling, dehumidifying, fan, and heating. It features a soft-touch control panel with an LED display and remote control. Key features include a built-in 24-hour timer, sleep mode, and a self-evaporating system. The unit operates within a temperature range of 16-32°C (cooling) and has an auto-defrost function. It is equipped with castor wheels for easy manoeuvrability.
Cooling Mode: Lowers room temperature, adjustable between 16-32°C with selectable fan speeds and swing function.
Heating Mode: Warms the room, adjustable temperature and fan speed.
Ventilating Mode: Circulates room air without cooling.
Drying/Dehumidifying Mode: Removes moisture (up to 50.4L/day), requires drainage hose connection for continuous operation.
Sleep Mode: Activates in cool or heat mode, gradually adjusts temperature and dims indicators for quiet operation.
Timer: Allows automatic start/stop scheduling.
Automatic Defrost: Activates at low temperatures to prevent frost buildup.
Drainage: Manual or continuous options available.
| SYMPTOM | INSPECTION | SOLUTION |
| The unit is not working | Check the mains supply | Insert the power cord securely into the wall outlet |
| Check if the water level indicator lights up? | Empty the drain pan. See Section 5.10 | |
| The unit works with reduced capacity | Check the room temperature. | The range of operating temperature is 5-35°C |
| Check if the air duct is blocked | Clear the obstacle. | |
| Check the air filter for dirt | Clean the air filter. See Section 7 | |
| Check if the room door or window is open. | Keep the door and windows closed. | |
| Check if the desired operating mode is selected and temperature is properly set. | Set the mode and temperature at proper set-point See Section 5 | |
| Water Leakage | The exhaust hose is detached. | Make sure the exhaust hose is securely attached. |
| Overflow while moving the unit. | Empty the water tank before transport. | |
| Check if the drain hose is kinked or bent. | Straighten the hose to avoid a trap existing. | |
| Excessive Noise | Check if the unit is securely positioned. | Place the unit on horizontal and firm ground. |
| Check if any loose, vibrating parts. | Secure and tighten the parts. | |
| Noise sounds like water flowing. | Noise comes from flowing refrigerant. This is normal. | |
| Error Codes | E0 | Communication faults between main PCB and display PСВ. |
| E1 | Ambient temperature sensor failure | |
| E2 | Coil temperature sensor failures. | |
| Ft | Condensate water high level alarm. |