Press POWER to turn the unit on (defaults to FAN mode). Press MODE to select desired operation mode. Press POWER again to turn off.
Choose from: Cool, Dehumidify, Fan, Heat, Sleep.
Set to turn OFF (when power on) or ON (when power off) with delay time. Cancel timer by pressing UP/DOWN until '00' is shown or pressing POWER.
| SYMPTOM | INSPECTION | SOLUTION |
| The unit is not working | Check the mains supply | Insert the power cord securely into the wall outlet |
|---|---|---|
| Check if the water level indicator lights up? | Empty the drain pan. See Section 5.10 | |
| The unit works with reduced capacity | Check the room temperature. | The range of operating temperature is 5-35°C |
| Check if the air duct is blocked | Clear the obstacle. | |
| Check the air filter for dirt | Clean the air filter. See Section 7 | |
| Check if the room door or window is open. | Keep the door and windows closed. | |
| Check if the desired operating mode is selected and temperature is properly set. | Set the mode and temperature at proper set-point See Section 5 | |
| Water Leakage | The exhaust hose is detached. | Make sure the exhaust hose is securely attached. |
| Overflow while moving the unit. | Empty the water tank before transport. | |
| Check if the drain hose is kinked or bent. | Straighten the hose to avoid a trap existing. | |
| Excessive Noise | Check if the unit is securely positioned. | Place the unit on horizontal and firm ground. |
| Check if any loose, vibrating parts. | Secure and tighten the parts. | |
| Noise sounds like water flowing. | Noise comes from flowing refrigerant. This is normal. | |
| Error Codes | E0 | Communication faults between main PCB and display PСВ. Check the wire harness of the display PCB for damage. |
| E1 | Ambient temperature sensor failure. Check connection or replace it. To clean or replace the temperature sensor. | |
| E2 | Coil temperature sensor failures. Check connection or replace it. To clean or replace the temperature sensor. | |
| Ft | Condensate water high level alarm. Empty the drain pan. See Section 5.10 |