Brand:
LG
Category: Home Appliance
Document Type: Parts/Service
Language: EN
Brand:
LG
Category: Home Appliance
Document Type: Parts/Service
Language: EN
Uploaded: Nov. 21, 2025, 8:07 p.m.
Manual Publish Date: 2005-05-01
| Pressing the "START/PAUSE" button | CHECKING ACTION | DISPLAY | CHECKING POINT | REMARK |
|---|---|---|---|---|
| None | Electric control & Temperature sensor | 18:88 ŁE 1 662 | Won't power up Defective LED Thermistor open Thermistor close | See test 1 Display: See page See test 2 |
| Once | Motor | 70~237 Measured Moisture Value. | Motor runs | See test 3 |
| Twice | • ELECTRIC TYPE Motor + Heater 1 (1250W) • GAS TYPE Motor + Valve |
Current Temp. | • ELECTRIC TYPE: Heater runs • GAS TYPE: GAS Valve runs (Display the Temperature of Inside drum.) |
Gas valve See test 7 |
| 3 times | • ELECTRIC TYPE Motor + Heater 1 + Heater 2 (5400W) • GAS TYPE Motor Type |
Current Temp. (5~70) | In normal state if displayed temp. is increasing. Temperature in 4min : 113°F (45°C) • Above: 1" on, 1" off beep sound • Under: 0.5" on, 0.5" off beep sound |
* Off automatically after 5 minutes |
| During check, If the door is open. | Motor & Heater Off + Lamp On + Buzzer beeps five times | dE | Door switch | See test 5 |
| During check, If the door is closed. | Motor & Heater Off + Lamp Off | 70~237 | Lamp | See test 6 |
| 4 times | Control Off | Auto Off |