Heating Sequence of Operation:

  • When thermostat calls for heat, combustion air inducer starts.
  • Combustion air pressure switch proves inducer operation.
  • After pre-purge (approx. 30 seconds), spark ignition energizes and solenoid valves open.
  • Spark ignites gas, ignition sensor proves flame, and combustion continues.
  • If flame not detected after 10-second trial, controller repeats ignition sequence twice before lockout (60 minutes).
  • Burners must light without crossover delay, flames predominantly blue and centered.
  • Fan energizes approximately 30 seconds after ignition.
  • When thermostat satisfied, gas valve closes; combustion air inducer shuts off after 30 seconds.
  • System fan shuts off approximately 150 seconds after gas valve de-energizes.

Troubleshooting and error codes

LED Status Table

Status Table (Responsive)

LED UNIT OPERATION
Slow Flash* Normal Operation - No call for heat
Fast Flash Normal Operation - Call for heat
2 Flashes System lockout - failed to detect or sustain flame
3 Flashes Pressure switch failed closed before CAI is energized or failed open after CAI is energized
4 Flashes High limit (S10) switch open
5 Flashes Flame sensed and gas valve (GV1) not energized
6 Flashes On-board microprocessor fault.
7 Flashes Pressure switch (S18) closed with inducer off.
8 Flashes Rollout switch (S47/S195) open. Cycle-power to reset.
Steady On Control board (A3) failure
Steady Off Internal control board (A3) failure or not power.