Warranty Summary
| EVENT NUMBER | EVENT DESCRIPTION | EVENT RESTRICTION | DETECTION INFORMATION | Limp Possible | Lockout Limit |
|---|---|---|---|---|---|
| 000 | NO FAULT | None | Displayed when all faults have been reset. | N/A | N/A |
| 002 | HIGH GROUND FAULT | No power | A ground fault is detected if leakage current to ground (truck chassis) exceeds 145 ma for more than .05 seconds. | N/A | 1 |
| 003 | FAILED DIODE | No power | Shorted diodes in main rectifier. | N/A | 1 |
| 004 | GFCO OPEN and not in REST | No power | GF Cutout Switch is open with the system not in REST. | N/A | 1 |
| 005 | DRIVE SYSTEM OVERTEMP | No Propel | Temperature exceeds a limit for a sufficient time. | N/A | 3 |