Brand: Honeywell
Category: Camera
Document Type: Manual
Language: EN
Available Languages: EN , ES
Uploaded: Nov. 21, 2025, 7:31 p.m.
Manual Publish Date: 2018-01-01
None
1. Connect the camera to a Honeywell Performance Series HQA DVR and log on as the admin user.
2. Right-click to display the shortcut menu, then click Camera Menu. The Menu Operation window opens.
3. Click Enter to display the camera's OSD menu.
4. To configure the camera, in the Menu Operation window, click the up/down arrows to move through the menu list, click the left/right arrows to change a menu setting, or click Enter to enter a submenu or execute a command.
5. After you have finished configuring the camera, scroll down to Exit, and then click Enter to exit the OSD menu. Right-click to close the Menu Operation window.
| OSD Menu Tree | 1st Level | 2nd Level | 3rd Level | 4th Level |
|---|---|---|---|---|
| Format | NTSC | Confirm/Cancel | ||
| PAL | Confirm/Cancel | |||
| Video Mode | 1080p @30/25 | Confirm/Cancel | ||
| 720p@30/25 | Confirm/Cancel | |||
| Backlight OFF Mode | HLC | LEVEL | 1-100 | |
| BACK | BACK/SAVE | |||
| BLC | LEVEL | Middle/High/Low | ||
| AREA | POSITION/SIZE | BACK/AGAIN | ||
| DEFAULT | ||||
| BACK | BACK/SAVE | |||
| WDR | LEVEL | 1-5 | ||
| BACK | BACK/SAVE | |||
| Image Adjust | SHARPNESS | 0-10 | ||
| BRIGHTNESS | 1-80 | |||
| SATURATION | 0-100 | |||
| GAMMA | USER/0.45/0.5/0.55/0.6/0.65/0.7/0.75/0.8/0.85/0.9/0.95/1 | |||
| 2DNR | LOW/MIDDLE/HIGH/OFF | |||
| 3DNR | LOW/MIDDLE/HIGH/OFF | |||
| BACK | BACK/SAVE | |||
| Exposure | MODE | AUTO | ||
| MANUAL | SHUTTER | 1/25(30);1/50(60);1/120(100);1/200(240);1/400(480);1/1000;1/2000;1/5000;1/10000;1/50000/X2/X4/X6/X8/X10/X15/X20/X25/X30 | ||
| BACK | BACK/SAVE | |||
| LEVEL | 1-80 | |||
| GAIN | 1-15 | |||
| SLOW SHUTTER | AUTO | SENS-UP | X2/X4X/X6/X8/X10/X15/X20/X25/X30 | |
| OFF | BACK | BACK/SAVE | ||
| BACK | BACK/SAVE |