| Fault/Symptom | Possible Cause | Solution |
| 9-1 The dryer does not start | ||
| The power supply plug peels off; | Insert the power plug into an appropriate receptacle to turn on the power. | |
| The local circuit is out of power; | Put on the local circuit. | |
| The door is not closed tightly; | Close the door tightly. | |
| The power button is OFF; | Press on the power button. | |
| The Start/Pause button has not been pressed; | The Start/Pause button has not been pressed. | |
| The condensate collection box is full; | Empty the tank. | |
| 9-2 The drying result is not good and the drying time is too long. | ||
| The drying program setting is not correct; | Set the drying program correctly. | |
| The filter screen has not been cleaned up. | Clean the filter screen. | |
| The condenser is blocked. | Clean the condenser. | |
| The amount of the loaded laundry exceeds the rated load. | Decrease the amount of the loaded laundry. | |
| The loaded laundry has not been spun dry. | Spin the loaded laundry dry. | |
| The vent duct is blocked. | Clean the vent duct. | |
| 9-3 Code:F2 (Error message: The drain pump is failed.) | ||
| Check if the tank is full with water; | Empty the tank and restart the dryer. | |
| Check if there are some lints around the floater; | Clear the lints. | |
| Check if the floater switch is failed; | Replace a new floater switch. | |
| Check if the pump is failed. | Replace a new pump. | |
| 9-4 Code:F3 (Error message: The NTC (near the filter) is short or cut out.) | ||
| Check if the connector are inserted properly. | Inserte the connector properly. | |
| Check if NTC is failed. | Replace a new NTC. | |
| Check if the PCB is failed. | Replace a new PCB. | |
| 9-5 Code:F4 (Error message: Temperature of the NTC (near the filter) does not change.) | ||
| Check if the filter is full with lints. | Clean the filter. | |
| Check if non-self-resetting thermal cut-out is cut. | Manual operation for resetting. | |
| Check if the heater is failed. | Replace a new heater. | |
| 9-6 Code:F9 (Error message: The NTC (near the heater) is short or cut out.) | ||
| Check if the connector are inserted properly. | Inserte the connector properly. | |
| Check if NTC is failed. | Replace a new NTC. | |
| Check if the PCB is failed. | Replace a new PCB. | |
| 9-7 Code:E6 (Error message: When the filter is full, Clean filter LED will be on, the consumer need clean the filter. If the filter is not cleaned 3 times continuous, E6 will be display.) | ||