Manual for FT10LV1L

Manual for FT10LV1L

Brand: DAIKIN

Category: Air Conditioning

Document Type: Manual

Language: EN

Uploaded: Sept. 12, 2025, 4:17 a.m.

Warranty Information

This manual does not explicitly state a warranty period.

Indoor Air Quality

The Plasma Generator effectively kills bacteria by damaging microbial DNA and surface structures, creating a refreshing environment.

Stylish Flat-Panel

Easy to clean flat front panel ensures the unit always looks new.

Wireless Remote Controller

  • Operates within 8 meters.
  • Adjustable fan speed (High/Medium/Low/Super Low/Auto).
  • Sleep mode auto-controls temperature for comfort.
  • Automatic airflow direction.
  • Electronic thermostat controls room temperature.
  • Real-time timer for automatic On/Off settings.
  • Turbo mode for rapid temperature achievement.

Auto Random Restart

Unit automatically restarts with last setting after power failure.

Self Diagnosis

Microprocessor detects and diagnoses faults indicated by blinking LEDs.

Built-in Starter (BIS)

Accurate thermal overload protector prevents overloading.

High Efficiency Heat Exchanger

3-fold structure heat exchanger with hydrophilic slit fin for improved airflow and heat exchange.

Rotary Compressor

Energy efficient with high output to weight ratio.

Space Saving

Super slim design for wall mounting maximizes floor space.

Troubleshooting and error codes

Error Code at 7 Segment Display Operation / Faulty Indication
Blink E1 Room sensor contact open / short
Blink E2 Indoor coil sensor contact open
Blink E3 Outdoor coil sensor contact open
Blink E4 Compressor overload/ Indoor coil sensor short/Outdoor coil sensor short
Blink E5 Gas leak
Blink E6 Pump faulty