Manual for PORTABLE AIR CONDITIONER 3 IN 1

Manual for PORTABLE AIR CONDITIONER 3 IN 1

Brand: CREATE

Category: Home Appliances

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: April 20, 2026, 7:44 p.m.

Warranty Information

Keep the manual and warranty card for future reference. Pass instructions to the next owner if applicable.

Basic Operation

  • Turn on the device using the power key.
  • Adjust temperature and time settings using Up/Down keys (temperature cannot be set in dehumidifying mode).
  • Set fan speed to high or low.
  • Engage Sleep mode for energy-saving and quiet operation.
  • Select Cooling, Dehumidifier, or Fan mode.
  • In Dehumidifier mode, only the fan operates at low speed.
  • The "Water full light" indicates the tank needs draining and the device will stop.
  • Set the timer for 1 to 24 hours.

Troubleshooting and error codes

PROBLEM POSSIBLE CAUSE SOLUTION
The air conditioner does not work. There is no electricity. Turn it on after connecting it to a socket with electricity.
The overflow indicator displays "FL". Discharge the water inside.
The ambient temperature is too low or too high. Recommend to use the machine in at the temperature of 7-35 °C (44-95 °F).
The cooling effect is not good. In cooling mode, the room temperature is lower than the set temperature. Change the set temperature.
In dehumidification mode, the ambient temperature is low. The machine is placed in a room with an ambient temperature over 17 °C (62 °F).
There is direct sunlight. Pull the curtains.
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat. Close doors and windows, and add new air conditioner.
Big Noise. The filter screen is dirty. Clean or replace the filter screen.
The air inlet or outlet is blocked. Clear obstructions.
The air conditioner is not placed on a flat surface. Put the air conditioner on a flat and hard place (to reduce noise).
Compressor does not work. Overheat protection starts. Wait for 3 minutes until the temperature is lowered, and then restart the machine.
The remote control does not work. The distance between the machine and the remote control is too far. Let the remote control get close to the air conditioner, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote control receiver. Let the remote control get close to the air conditioner, and make sure that the remote control directly faces to the direction of the remote control receiver.
Batteries are dead. Replace batteries.
Displays 'E1'. The pipe temperature sensor is abnormal. Check the pipe temperature sensor and related circuitry.
Displays 'E2'. The room temperature sensor is abnormal. Check the room temperature sensor and related circuitry.