| Problem | Possible cause | Possible solution |
|---|---|---|
| The appliance does not turn on when pressing ON/OFF button. | The appliance is not plugged in. There is no current. |
Plug in the appliance. Check if a circuit breaker has flipped off and in case reset circuit breaker. Otherwise wait. |
| An internal safety device prevents the appliance from being restarted until four minutes have elapsed since it was last turned off. | If you turn the appliance off wait 4 minutes to restart it. | |
| The appliance works for a short time only. | Room temperature is lower than the setting temperature. | Reset the setting temperature. |
| There are bends or kinks in the air exhaust hose. | Position the air exhaust hose correctly, keep it as short as possible and free of bends. | |
| The appliance turns on and off rapidly. | The air filter is soiled. | Turn off the appliance and clean the filter. |
| Something is preventing the air from being discharged. | Check and remove any obstacles obstructing air discharge. | |
| The appliance is working in air conditioning modes, but does not cool the room properly. | Unfavourable ambient conditions: windows, doors and/or curtains are open. | Close doors, windows and curtains. |
| Unfavourable ambient conditions: the room contains powerful heat sources. | Eliminate the heat sources. | |
| The air filter is soiled. | Turn off the appliance and clean the filter. | |
| Incorrect temperature setting. | Setting temperature should be lower than ambient temperature. | |
| Compressor shut-off. | Wait approximately 4 minutes and listen for compressor to restart when set in air conditioning mode. | |
| Unpleasant odours during operation. | Air intakes and/or air outlets are obstructed. | Check and remove any obstacles obstructing air in- or/and out takes. |
| The technical specification of the appliance is not adequate for the room size in which it is located. | Reconfirm that the cooling capacity is adequate for the room in which it is located. | |
| Unpleasant odours in the air may enter the appliances and spread. | Turn off the appliance and clean the filter. | |
| Dust is being discharged from the air outlet. | The air filter is soiled. | Turn off the appliance and clean the filter. |
| Dust may accumulate in the appliance if it is shut down for an extended period and not covered. | ||
| The appliance is noisy and vibrates too much. | The ground is not level. | Place the appliance on a flat, level surface. |
| The air filter is soiled. | Turn off the appliance and clean the filter. | |
| The appliance is noisy. | In order for the appliance to work, the appliance produces some noises that are considered normal. At the top of the appliance, a sound of rushing air being moved by the fan can be heard. High efficient compressors may occur high-pitched sound during air conditioning operation. A gurgling or hissing noise is normal during operation. This is caused by the flow of refrigerant. | |
| The remote control does not turn on. | The batteries are empty. | Replace the batteries. |
| The appliance does not receive signal from the remote control. | The signal between the remote control and signal receiver is interrupted. | The remote control must be no more than 5 meters away from the appliance without obstacles between the remote control and the appliance. |
| The error messages FL, E2, E4, E6. E7 appear on the display. | The appliance has a self diagnosis system to identify a number of malfunctions. | → Chapter 8.1 "Self-diagnosis", Page 22 |
| Error code | Description | Solution |
|---|---|---|
| FL | Internal tank full | Empty the internal tank (→Chapter 6.3.2 "Draining the internal tank", Page 19). If the Error code continues to appear despite the internal tank being empty, please contact an authorized service technician. |
| E2 | Sensor failure | Please contact an authorized service technician. |
| E4 | Sensor failure | Please contact an authorized service technician. |
| E6 | Motor failure | Please contact an authorized service technician. |
| E7 | PCB failure | Please contact an authorized service technician. |