Warranty Summary
Power-Up/Outdoor Reset Sequence:
Operational Response:
| Alert Codes | Inverter Code | Inverter LED Flash Code | Priority | Alarm Description | Possible Causes and Clearing Alarm |
|---|---|---|---|---|---|
| E 105 | N/A | N/A | Moderate | Outdoor control lost communication with thermostat or indoor unit. | Check wiring, noise sources. Resets after communication restored. |
| E 120 | N/A | N/A | Moderate | Delay in outdoor unit responding to system. | Check wiring. Clears automatically. |
| E 124 | N/A | N/A | Critical | Wi-FiĀ® thermostat lost communication with outdoor unit. | Check wiring, power cycle. Clears after communication re-established. |
| E 125 | N/A | N/A | Critical | Hardware problem with outdoor control. | Replace outdoor control. Clears after 300 seconds if recovered. |
| E 131 | N/A | N/A | Critical | Outdoor unit control parameters corrupted. | Reconfigure system. Replace control if needed. |
| E 132 | N/A | N/A | Critical | Internal software error. | Replace outdoor control. |
| E 180 | N/A | N/A | Critical | Outdoor ambient temperature sensor malfunctioned. | Check/replace sensor. Clears upon configuration or normal values. |