Brand: AEG
Category: Heating
Document Type: Manual
Language: EN
Brand: AEG
Category: Heating
Document Type: Manual
Language: EN
Uploaded: April 20, 2026, 7:55 p.m.
For guarantee, please refer to the respective terms and conditions of supply for your country.
| What to do when...? | For the User | For the specialist |
|---|---|---|
| • the storage heater does not get hot | Check whether... - the selector knob is set to position 3. - the corresponding fuses in your fuse box are defective or the Fl switch has switched off. Eliminate the cause! |
Check whether... - the control of the heating element contactor is OK. - there is a voltage at terminals L1/L2/L3. - whether the safety temperature limiter (F1) has triggered. |
| If the following day the storage heaters have still not heated up, call a specialist. | ||
| • the storage heater housing should get extraordinarily hot even in mild weather | Check whether - the fan can be switched on with the room temperature regulator. If not, call a specialist. - the fluff screen in the air inlet grille is blocked. Eliminate cause as described in section 1.4.1! |
Check whether... - the room temperature regulator has switched on and voltage is applied at terminal LE. - the fans are turning. - the safety temperature regulator (N5, see page 3, fig. 1) in the air outlet has switched off. - the control signal Z1 of the charging control unit is applied at terminal A1/Z1 in the storage heater. |