Warranty Information

The warranty covers manufacturing or material defects for 24 months for domestic use and 12 months for commercial use.

Operation Summary

The open vented (non-pressurised) appliance maintains a set water temperature. Cold water replenishes as hot water is drawn. It has a temperature selector for adjusting the output temperature and a heat-up indicator. During heating, expansion water may drip from the tap. The appliance is equipped with a high limit safety cut-out to prevent overheating. For safe operation, it must be used with open vented taps and never subjected to water pressure.

Troubleshooting and error codes

Problem Cause Remedy
The appliance does not supply hot water. The temperature selector is set to "OFF / frost protection". Switch the appliance ON by turning the temperature selector.
No power at the appliance. Check the plug / fuses in the distribution board. Call your qualified contractor.
Water can only be drawn at a reduced rate. The aerator in the tap is scaled up. Descale / replace the aerator.
Loud boiling noises inside the appliance. The appliance is scaled up. Call your qualified contractor.